บทความ

กำลังแสดงโพสต์จาก มีนาคม, 2015
Note for I Cisco aironet 1600 series config for SAP enable WEBUI Console to your Access Point  Create user / password / open both radio and open GUI after this  you can access WebGUI to Management  config terminal username admin pri 15 sec admin int dot110 no shutdown int dot111 no shutdown ip http server ip http authen local line vty 0 4 login local Open IP address to Access to WebUI  bridge irb bridge 1 route ip interface bvi 1 ip address 192.168.1.10 255.255.255.0 no shut